Home      Products     Endress+Hauser     Level       FDU93 Ultrasonic measurement sensor
  • FDU93 Ultrasonic measurement sensor

FDU93 Ultrasonic measurement sensor

  • Product Item : FDU93-RG2A
  • Category: Level
  • Measuring Principle:Ultrasonic
  • Characteristic / Application:Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
  • Supply / Communication:4-wire (HART, Profibus DP)
  • Max. measurement:distance 10 m (33 ft)
  • INQUIRY   EMAIL

Endress Hauser FDU93 Prosonic Ultrasonic Measure Instruments

 

Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range
up to 25m)

 

The FDU93 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in liquids 25m (85ft), solids 15m (50ft).

 

Field of application

Sensor for continuous, non-contact level measurement of fluids and of bulk materials in silos, on belts, stockpiles and in crushers. Also for flow measurement in open channels and at weirs. Typically used in measurements in low structural heights.

 

Process connection: Thread

Temperature: -40 to +95°C (-40 to +203°F)

Pressure: +0.7 to +3bar (+10 to +43psi)

Maximum measuring range: Liquids 25m (85ft), solids 15m (50ft)

Blocking distance: 0.6m (2ft)

International explosion protection certificates

Measuring Principle

Ultrasonic

Characteristic / Application

Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between seonsor and transmitter

Supply / Communication

4-wire (HART , Profibus DP) 

Accuracy

+/- 2mm + 0.17% of measured distance

Ambient temperature

-40 °C ... 95 °C 
(-40 °F ... 203 °F)

Process temperature

-40 °C ... 95 °C 
(-40 °F ... 203 °F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 3 bar abs 
(10 psi ... 43 psi)

Main wetted parts

UP (unsaturated polyester)
Silicon / Al PTFE coated

Process connection

G / NPT 1"

Blocking distance

0.6 m (2 ft)

Max. measurement distance

25 m (85 ft)

Output

Transmitter:
4 ... 20 mA HART
Profibus DP

Certificates / Approvals

ATEX, FM, CSA, IEC Ex, NEPSI

Options

Second 4...20mA output

Components

Transmitter:
FMU90, FMU95