Home      Products     Endress+Hauser     Level       FMB50 Hydrostatic Level measurement
  • FMB50 Hydrostatic Level measurement

FMB50 Hydrostatic Level measurement

  • Product Item : FMB50-AA21JA1HGACGJB2U
  • Category: Level
  • Measuring Principle:Hydrostatic
  • Supply / Communication:4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex) 
  • Process pressure absolute / max. overpressure limit:40 bar (600 psi)
  • Main wetted parts:Alloy C  316L optional coating AuPt 
  • INQUIRY   EMAIL

Hydrostatic Level measurement Deltapilot FMB50

Compact pressure sensor with the Contite measuring cell for hydrostatic level measurement


The compact Deltapilot FMB50 transmitter with the condensate resistant Contite measuring cell is typically used in the process and hygienic applications.
It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. For use in SIL2 safety systems.

Benefits

  • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects

  • Modular concept for easy replacement of display or electronics

  • Seamless and independent system integration (HART/PA/FF)

  • Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

  • International usage thanks to a wide range of approvals

Field of application

For level and/or pressure measurement.

  • Process connections: Thread, flanges and flush-mounted hygienic connections

  • Process temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)

  • Measuring range: 0.1 to 10bar (1.5 to 150psi)

  • Accuracy: ±0.2%, ±0.1% (option)

  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates

Features and specifications

Continuous / Liquids level
Measuring Principle Hydrostatic
Characteristic / Application Pressure transmitter for hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
- hermetically welded
- absolute condensation tight
- climate-resitant
- long-term stable
- Lowest temperature influences

Compact version
Supply / Communication 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC (Non Ex)
Accuracy Standard 0,2%
Optional 0,1%
Long term stability 0,05% of URL/year
Ambient temperature -40°C...85°C
(-40°F...185°F)
Process temperature -10°C...100°C
(14°F...212°F)
Process pressure absolute / max. overpressure limit 40 bar (600 psi)
Pressure measuring range 100mbar...10bar
(1.5psi...150psi)
Main wetted parts Alloy C
316L
optional coating AuPt
Process connection Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 1 1/2"...4",
JIS 10K
Process connection hygienic Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRD
Max. measurement distance 100m (328ft) H2O
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

Safety approvals Overfill prevention WHG
SIL

Design approvals EN10204-3.1
NACE MRO103

Hygienic approvals 3A, EHEDG
CoC ASME-BPE

Marine approval GL/ ABS/ LR/ BV/ DNV

Drinking water approvals KTW/ NSF/ ACS

Pressure measurement
Measuring Principle Hydrostatic
Characteristic Pressure transmitter for hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
- hermetically welded
- absolute condensation tight
- climate-resitant
- long-term stable
- Lowest temperature influences

Compact version
Supply voltage 4...20mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)

Reference Accuracy Standard 0,2%
Optional 0,1%
Long term stability 0,05% of URL/year
Process temperature -10°C...100°C
(14°F...212°F)
Ambient temperature -40°C...85°C
(-40°F...185°F)
Measuring cell 100mbar...10bar
(1.5psi...150psi)
Smallest calibratable span 10 mbar (1.45 psi)
Vacuum resistance 0 mbar abs.
Max. Turn down 100:1
Max. overpressure limit 40 bar (600 psi)
Process connection Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 1 1/2"...4",
JIS 10K
Hygienic Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRD
Material process membrane 316L, AlloyC
Gold-Rhodium
Material gasket None, measuring cell welded
Fill fluid Inert oil,
Synthetic oil
Material housing 316L, Die-cast aluminum
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

Safety approvals Overfill prevention WHG
SIL

Design approvals EN10204-3.1
NACE MR0103

Hygienic approvals 3A, EHEDG
CoC ASME-BPE

Marine approvals GL/ ABS/ LR/ BV/ DNV

Drinking water approvals KTW/ NSF/ ACS

Specialities Modularity to differential pressure and process pressure devices (replacable display, universal electronics)

Diagnostic functions

Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)