Home      Products     Endress+Hauser     Pressure       PMP51 Absolute and gauge pressure transm
  • PMP51 Absolute and gauge pressure transmitter
  • PMP51 Absolute and gauge pressure transmitter
PMP51 Absolute and gauge pressure transmitterPMP51 Absolute and gauge pressure transmitter

PMP51 Absolute and gauge pressure transmitter

  • Product Item : PMP51-AA21JD1PGBRKCB1
  • Category: Pressure
  • Measuring Principle:Hydrostatic
  • Characteristic / Application:Smart and reliable pressure transmitter, with piezoresistive measuring cell and metal welded process isolating diaphragm 
  • Pressure measuring range:1bar...400bar  (15psi...6000psi)
  • Max. measurement distance:4000m (13.123ft) H2O
  • INQUIRY   EMAIL

Absolute and gauge pressure Cerabar PMP51

Digital pressure transmitter with welded metal sensor for measurement in gases, steam or liquids


The Cerabar PMP51 digital pressure transmitter with metal membrane is typically used in process and hygiene applications for pressure, level, volume or mass measurement in liquids or gases. PMP51 is designed for high pressure applications up to 400bar. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 and IEC 61511.

Benefits

  • Accurate measurement of the process value even in the case of changing process temperature

  • Process safety assured with small flush mounted process connections in hygienic applications

  • For process pressure monitoring up to SIL2, certified to IEC 61508 and IEC 61511

  • Modular concept for easy replacement of display or electronics

  • Easy menu-guided commissioning via on-site display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

  • Seamless and independent system integration (HART/PA/FF)

Field of application

Single chamber aluminum or stainless steel (316L) housing.

  • Process connections: Threads, flanges or hygienic connections

  • Process temperature: -40 to +130°C (-40 to +266°F), 150°C (302°F) for 1h

  • Measuring range: -1/0 up to +400bar (-15/0 up to +6,000psi)

  • Accuracy: ±0.15%, "Platinum" ±0.075%

  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals

Features and specifications

Continus Liquids Level

 
Measuring Principle Hydrostatic
Characteristic / Application Smart and reliable pressure transmitter, with piezoresistive measuring cell and metal welded process isolating diaphragm 
Supply / Communication 4 ..20mA HART: 
11,5...45V DC 
Ex ia: 11,5...30V DC
PROFIBUS PA
FOUNDATION Fieldbus 
Accuracy 0,15% 
Platinum 0,075% 
Long term stability 0,1% of URL/year 
Ambient temperature -40°C...85°C 
(-40°F...185°F) 
Process temperature -40°C...125°C 
(-40°F...275°F)   
Process pressure absolute / max. overpressure limit 600bar (9000psi)   
Pressure measuring range 1bar...400bar 
(15psi...6000psi)   
Main wetted parts 316L   
Process connection Threads
Flanges (DIN, ASME, JIS)
Hygienic connections
Tri-Clamp ISO2852
Max. measurement distance 4000m (13.123ft) H2O   
Output 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus 
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
SIL
EN10204-3.1
NACE
CoC ASME-BPE
3A, EHEDG
Marine 
Options local display 
Application limits Measuring cell: Metal welded 
If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure   

Pressure measurement

 
Measuring Principle Hydrostatic
Characteristic Smart and reliable pressure transmitter, with piezoresistive measuring cell and metal welded process isolating diaphragm 
Supply voltage 4...20mA HART
11,5...45V DC (Non Ex):
Ex ia: 11,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Reference Accuracy Standard 0,15%
Platinum 0,075% 
Long term stability < 0,1% of URL/year
< 0,175% of URL/ 5 years 
Process temperature -40°C...130°C
(-40°F...266°F
150°C for 1h
(302°F for 1h)
Ambient temperature -40°C...85°C 
(-40°F...185°F) 
Measuring cell 400mbar...400bar
(15psi...6000psi)
relative/ absolute
Smallest calibratable span 20 mbar (2.9 psi) rel./ abs.
Vacuum resistance 10 mbar (1.45 psi) abs.
Max. Turn down 20:1
Max. overpressure limit 600bar (9000psi) 
Process connection Thread:
G1/2...G2, MNPT1/2...MNPT2
Flange:
DN25...DN80,
ASME 1 1/2"...4",
Hygienic Tri-Clamp
DIN11851
NEUMO
Varivent N
SMS
DRD
Material process membrane 316L, AlloyC,
Tantal,
Rhodium>Gold
Material gasket None, measuring cell welded
Fill fluid Silicone oil,
Inert oil
Material housing Die-cast aluminum,
AISI 316L
Output 4...20 mA
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus 
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
SIL
EN10204-3.1
NACE
3A, EHEDG
CoC ASME-BPE
GL/ ABS/ LR/ BV/ DNV Marine
NSF Drinking water
Options Display
PWIS free