Home      Products     Endress+Hauser     Pressure       PMD75 Differential pressure transmitter
  • PMD75 Differential pressure transmitter
  • PMD75 Differential pressure transmitter
  • PMD75 Differential pressure transmitter
PMD75 Differential pressure transmitterPMD75 Differential pressure transmitterPMD75 Differential pressure transmitter

PMD75 Differential pressure transmitter

  • Product Item : PMD75-ABC7D21BAAU
  • Category: Pressure
  • Measuring Principle:Differential pressure
  • Accurac:Standard: 0.05% Platinum: up to 0.035%
  • Process pressure absolute / max. overpressure limit:420bar (6300psi)
  • Pressure measuring range:10mbar...40bar (0.15psi...600 psi)
  • INQUIRY   EMAIL

Differential pressure Deltabar PMD75

Differential pressure transmitter with metal sensor for measurement of pressure differences


The Deltabar PMD75 differential pressure transmitter with with piezoresistive sensor and welded metallic membrane is used in all industries for continuous measurement in liquids, vapours and gases. The 3-key operation enables simple and reliable commissioning and operation. The integrated HistoROM data module allows easy management of process and device parameters. Designed according to IEC 61508 for use in SIL2/3 safety applications.

Benefits

  • Best accuracy, reproducibility and long-term stability

  • Highest safety due to gastight feedthrough with capabilities up to SIL2/3, certified to IEC 61508

  • Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Cost savings with modular concept for easy replacement of sensor, display or electronics

  • Overload-resistant up to 420bar / 42MPa / 6300psi, function-monitored

  • Seamless and independent system integration (HART/PA/FF)

Field of application

For level, volume or mass measurement in liquids, differential pressure monitoring as well as flow measurement (volume or mass flow) in conjunction with primary elements in gases, vapors and liquids.

  • Process connections: Threads

  • Process temperature: -40 to +85°C (-40 to +185°F)

  • Measuring ranges: 0.25mbar to 40bar (0.0036 to 600psi)

  • Accuracy: ±0.05%, "Platinum" ±0.025% (optional)

  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals

Features and specifications

Continuous / Liquids  
Measuring Principle Differential pressure
Characteristic / Application Digital transmitter with metallic measuring diaphragms
Modular transmitter
Long term stability
High static pressure/Overload resistance
Enhanced safety via self diagnostic functions
Secondary process barrier
Supply / Communication 4...20 mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Accuracy Standard: 0.05%
Platinum: up to 0.035%
Long term stability 0,05% of URL/year
Ambient temperature -40°C...85°C
(-40°F...185°F)
Process temperature -40 °C...85 °C
(-40 °F...185 °F)
Process pressure absolute / max. overpressure limit 420bar (6300psi)
Pressure measuring range 10mbar...40bar
(0.15psi...600 psi)
Main wetted parts Alloy C276
316L
Monel
Tantalum
Process connection 1/4-18NPT
RC1/4"
Max. measurement distance 400m (1.312ft) H2O
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
SIL
WHG/ Overfill prevention
EN10204-3.1
NACE
Marine
Gas  
Measuring Principle Differential pressure
Product headline Digital transmitter with metallic measuring diaphragms
Modular transmitter
Long-term stability
High static pressure/Overload resistance
Enhanced safety via self diagnostic functions
Secondary process barrier
Max. measured error 0,075%
"PLATINUM" 0,05%
Max. process pressure max. 420bar
(max. 6.091 psi)
Medium temperature range Temperature gradient from pressure piping
Display/Operation Option
Outputs 4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Digital communication HART
PROFIBUS PA
FOUNDATION Fieldbus
Hazardous area approvals ATEX
FM
CSA
NEPSI
IECEx
SIL
NACE
Schiffbau GL
WHG/ Überfüllsicherung
EN 10204-3.1
Liquids  
Measuring Principle Differential pressure
Product headline Digital transmitter with metallic measuring diaphragms
Modular transmitter
Long-term stability
High static pressure/Overload resistance
Enhanced safety via self diagnostic functions
Secondary process barrier
Max. measured error 0,075%
"PLATINUM" 0,05%
Max. process pressure max. 420bar
(max. 2.175 psi)
Medium temperature range Temperature gradient from pressure piping
Display/Operation Option
Outputs 4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Digital communication HART
PROFIBUS PA
FOUNDATION Fieldbus
Hazardous area approvals ATEX
FM
CSA
NEPSI
IECEx
SIL
NACE
Schiffbau GL
WHG/ Überfüllsicherung
EN 10204-3.1
Pressure  
Measuring Principle Differential pressure
Characteristic Digital transmitter with metallic measuring diaphragms
Modular transmitter
Long-term stability
High static pressure/Overload resistance
Secondary process barrier
Supply voltage 4...20mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)

Reference Accuracy Standard: 0.05%
Platinum: up to 0.035%
Long term stability 0,05% of URL/year
0,125% of URL/5 years

Process temperature -40°C...85°C
(-40°F...185°F)
Ambient temperature -40°C...85°C
(-40°F...185°F)
Measuring cell 10mbar...40bar
(0.4inH2O...600psi)
Smallest calibratable span 1 mbar (0.015 psi)
Vacuum resistance 50 mbar (7.25psi)
Max. Turn down 100:1
Max. overpressure limit On one side:
420 bar
(6300psi)
Process connection 1/4-18NPT
RC1/4"
Material process membrane 316L, AlloyC,
Tantal,
Gold-Rhodium
Material gasket Viton, PTFE, EPDM, NBR
Fill fluid None
Material housing 316L, Die-cast aluminum
Communication 4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

Safety approvals WHG/ Overfill prevention
SIL

Design approvals NACE MR0103
EN10204-3.1

Marine approvals GL/ ABS

Specialities Diagnostic functions
Steam  
Measuring Principle Differential pressure
Product headline Digital transmitter with metallic measuring diaphragms
Modular transmitter
Long-term stability
High static pressure/Overload resistance
Enhanced safety via self diagnostic functions
Secondary process barrier
Max. measured error 0,075%
"PLATINUM" 0,05%
Max. process pressure max. 420bar
(max. 6.091 psi)
Medium temperature range Temperature gradient from pressure piping
Display/Operation Option
Outputs 4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Digital communication HART
PROFIBUS PA
FOUNDATION Fieldbus
Hazardous area approvals ATEX
FM
CSA
NEPSI
IECEx
SIL
NACE
Schiffbau GL
WHG/ Überfüllsicherung
EN 10204-3.1