Home      Products     Endress+Hauser     Analysis       CYK10 Digital measuring cable

CYK10 Digital measuring cable

  • Product Item : CYK10-A101
  • Category: Analysis
  • Measuring Principle:Sensor ORP / Redox
  • Application:Measuring cable for contactless, inductive, digital transmission of measurement signals.
  • Installation:Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter.
  • Material:PEEK 
  • INQUIRY   EMAIL

Digital measuring cable CYK10
Memosens data cable for all sensors with Memosens plug-in head


CYK10 guarantees absolute water-proof connection of Memosens sensors to the transmitter. Its inductive coupling shows no contact corrosion and guarantees galvanic isolation of transmitter and medium. Simply forget about limited cable length, interfering potentials or moisture and benefit from completely safe and reliable signal transmission.

 

Benefits

  • Maximum process safety through non-contact, inductive and digital signal transmission: No contact corrosion, absolutely watertight, no interference potential.

  • Increased availability of the measuring point: Digital data transmission provides an automatic error message if the signal is lost.

  • More flexibility in plant planning and installation: Cable length up to 100 m is possible.

  • Approved for hazardous area use.

Field of application

The Memosens data cable CYK10 is applied in Memosens systems measuring the following parameters:

  • pH/ORP

  • Dissolved oxygen (amperometric)

  • Conductive conductivity

  • Disinfection

Features and specifications

Conductivity / ORP / Redox / PH
Measuring Principle Sensor ORP / Redox
Application Measuring cable for contactless, inductive, digital transmission of measurement signals.
Installation Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter.
Characteristic Inductive, digital transmission of measurement signals and energy.
Not influenced by moisture, EMC-fields and corrosion.
Measurement range High impedance cable not necessary.
Design Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head
No open contacts, resistant against humidity.
Material PEEK
Dimension Diameter: 6,3 mm / 0,25"
Cores: 2x2 cores, twisted paires
Length: up to approx. 100 m/328 ft
Process temperature -20... 135°C
Process pressure max. 50 bar/725 psi at 135°C/275°F.
temperature sensor For digital sensors with inductive plug-head with and without temperature sensor.
Ex certification ATEX II 1G Ex ia IIC T3/T4/T6
FM, CSA IS Cl.1 Div 1 Gr. A-D
ATEX, NEPSI II 3G Ex nL IIC
TIIS
Ingres protection IP68
Additional Certifications Also available as TÜV approved SIL version.
Oxygen
Measuring Principle Sensor ORP / Redox
Application Measuring cable for contactless, inductive, digital transmission of measurement signals.
Installation Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter.
Characteristic Inductive, digital transmission of measurement signals and energy.
Not influenced by moisture, EMC-fields and corrosion.
Design Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head
No open contacts, resistant against humidity.
Material PEEK
Dimension Diameter: 6,3 mm / 0,25"
Cores: 2x2 cores, twisted paires
Length: up to approx. 100 m/328 ft
Process temperature -20... 135°C
temperature sensor For digital sensors with inductive plug-head with and without temperature sensor.
Additional Certifications Also available as TÜV approved SIL version.