Home      Products     Endress+Hauser     Level       FMU90 Ultrasonic level measurement
  • FMU90 Ultrasonic level measurement

FMU90 Ultrasonic level measurement

  • Product Item : FMU90-R11CA111AA3A
  • Category: Level
  • Measuring Principle:Ultrasonic
  • Characteristic / Application:Separated version with Field housing or top hat rail housing for control cabinet instrumentation, up to 6 relays for pump / rake / limit control, 1 or 2 channel version
  • Accuracy:+/- 2mm + 0.17% of measured distance
  • Communication:up to 2x 4 ... 20 mA HART Profibus DP
  • INQUIRY   EMAIL

Ultrasonic measurement Time-of-Flight Prosonic FMU90

Transmitter in housing for field or top hat rail mounting for up to 2 sensors FDU90/91/92/93/95


Prosonic FMU90 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids. Also the flow measurement in open channels and weirs is possible as the simultaneous measurement of level and flow in a storm water overflow basin with only 1 sensor. Up to 6 relays for tendency alarm, flow pulse output or backwater/sludge alarm, 1 or 2 channel version.

Benefits

  • Simple, menu-guided operation with 6-line plain text display, 15 languages selectable

  • Envelope curves on the display for quick and simple diagnosis

  • Easy operation, diagnosis and measuring point documentation with the supplied "FieldCare" operating program

  • Time-of-Flight correction via integrated or external temperature sensors

  • Linearisation (up to 32 points, freely configurable) for the most common flumes and weirs
    pre-programmed and selectable

  • Online calculation of the flume-/weir-flows via integrated flow curves

  • Automatic detection of the sensors FDU9x

Field of application

Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45m (148ft) and level limit detection. Pump control, rake control and as option: additional pump control function.

  • Calculations: Average, difference, sum

  • Application flow: Flow measurement in open channels and weirs with 1 or 2 sensors

  • Flow measurement with back water or sludge detection

  • Up to 3 totalizers and 3 counters

  • Counting or time pulse output for control of external units

Features and specifications

Continuous / Liquids  
Measuring Principle Ultrasonic
Characteristic / Application Separated version with Field housing or top hat rail housing for control cabinet instrumentation, up to 6 relays for pump / rake / limit control, 1 or 2 channel version
Supply / Communication 90 ... 253 VAC
10.5 ... 32 VDC
up to 2x 4...20mA HART
Profibus DP

Accuracy +/- 2mm + 0.17% of measured distance

Ambient temperature -40 °C ... 60 °C
(-40 °F ... 140 °F)
Communication up to 2x 4 ... 20 mA HART
Profibus DP

Certificates / Approvals FMU allowed to operate FDU9x in Ex-Zone
CSA GP (tested according UL)
Components Sensors FDU9x
Continuous / Solids  
Measuring Principle Ultrasonic
Characteristic / Application Separated version with Field housing or top hat rail housing for control cabinet instrumentation, up to 6 relays for limit control, 1 or 2 channel version
Supply / Communication 90 ... 253 VAC
10.5 ... 32 VDC
up to 2x 4...20mA HART
Profibus DP

Accuracy +/- 2mm + 0.17% of measured distance

Ambient temperature -40 °C ... 60 °C
(-4 °F ... 140 °F)
Communication up to 2x 4 ... 20 mA HART
Profibus DP

Certificates / Approvals FMU allowed to operate FDU9x in Ex-Zone
ATEX: FMU for field housing
CSA GP (tested accordung UL)
Components Sensors FDU9x
Liquids  
Measuring Principle Ultrasonic
Product headline Separated version with field housing or top hat rail housing for control cabinet instrumentation, up to 6 relays for tendency alarm, flow pulse output or backwater / sludge alarm, 1 or 2 channel version
Sensor features pre-programed flow curves for typical open channel measurement

Degree of protection IP66 (Fieldhousing)
IP20 (top hat rail housing)
Display/Operation Illuminated display, 6 line graphic display with country specific menu guidance, on-site diagnosis with envelope curve on display
Outputs 4...20mA HART
Optional:
second 4...20 mA output (e.g. for 2 times flow measurement
1 relay (standard)
Optional:
3 or 6 relays
Inputs up to 2 FDU9x sensors
Digital communication HART
Profibus DP

Hazardous area approvals FMU allowed to operate FDU9x in Ex-zone