Home      Products     Endress+Hauser     Flowmeter       B 150 Thermal mass flowmeter
  • B 150 Thermal mass flowmeter

B 150 Thermal mass flowmeter

  • Product Item : 6BABL3-AADACAASAGA1G
  • Category: Flowmeter
  • Measuring Principle:Thermal
  • Nominal diameter range:DN 80 to 1500 (3 to 60")
  • Max. process pressure:20 bar g (290 psi g)
  • Digital communication:HART
  • INQUIRY   EMAIL

Proline t-mass B 150 Thermal mass flowmeter

The flowmeter for cost-effective measurement and easy monitoring of utility gases


The t-mass B 150 insertion version is suitable for large pipelines or rectangular ventilation ducts. It is designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at sub-metering applications. Its 4-wire technology is contained within a rugged compact aluminum housing. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.

Benefits

  • Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts

  • Optimal process monitoring – easy measurement even at low pressures and flow velocities

  • Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free

  • Reliable flow trending – multivariable measurement

  • Fast and efficient commissioning – guided operating menus

  • High plant availability – self-diagnostics and error monitoring

  • Automatic recovery of data for servicing

Field of application

  • Measuring principle is characterized by a high operable flow range and direct mass flow measurement

  • Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts.

Device properties

  • Insertion version for nominal diameter DN 80 to 1500 (3 to 60")

  • Installation and removal of sensor without process interruption

  • Easy installation

  • Device in compact version with DC 24 V power supply

  • 4-20 mA HART, pulse/frequency/switch output

  • Compact and robust transmitter

Features and specifications

Measuring Principle Thermal
Product headline The flowmeter for cost‐effective measurement and easy monitoring of utility gases. Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts.
Sensor features Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost‐effective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement. Insertion version for nominal diameter DN 80 to 1500 (3 to 60"). Installation and removal of sensor without process interruption.
Transmitter features Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing. Device in compact version with DC 24 V power supply. 4‐20 mA HART, pulse/frequency/switch output.
Nominal diameter range DN 80 to 1500 (3 to 60")
Wetted materials Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L); 1.4435 (316L)
Connection:
Compression fitting: 1.4404 (316L)
Sealing ring: EPDM; HNBR; 1.4401 (316)
Clamping ring: PEEK 450G
Measured variables Mass flow, temperature, corrected volume flow, FAD volume flow
Max. measured error 3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")
Measuring range 20 to 720 000 kg/h (45 to 1 587 600 lb/h)
20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
(for air, depending on chosen option of ordering feature "Calibration flow")
Max. process pressure 20 bar g (290 psi g)
Medium temperature range –40 to +100 °C (–40 to +212 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Transmitter housing material AlSi10Mg, coated
Degree of protection IP66/67, type 4X enclosure
Display/Operation 4‐line display with push Buttons
Configuration via local display and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs Status input
Digital communication HART
Power supply DC 18 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus
Other approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR CRN