Home      Products     Endress+Hauser     Pressure       PMP75 Absolute and gauge pressure transm
  • PMP75 Absolute and gauge pressure transmitter
  • PMP75 Absolute and gauge pressure transmitter
PMP75 Absolute and gauge pressure transmitterPMP75 Absolute and gauge pressure transmitter

PMP75 Absolute and gauge pressure transmitter

  • Product Item : PMP75-HBC1F28B3GAA1
  • Category: Pressure
  • Measuring Principle:Hydrostatic
  • Pressure measuring range:100mbar...400bar (1.5psi...5800psi)
  • Main wetted parts:Alloy C276 316L Monel Tantalum PTFE-Foil
  • Process connection:Threads  Flanges (DIN, ASME, JIS) with flush membrane Tri-Clamp ISO02852 Hygienic connections
  • INQUIRY   EMAIL

Absolute and gauge pressure Cerabar PMP75,Predecessor: PMC631, PMP635

Digital pressure transmitter with fully welded diaphragm seal for measurement in gases or liquids


The Cerabar PMP75 digital pressure transmitter with metal diaphragm seal is typically used in process and hygiene applications for pressure, level, volume or mass measurement in liquids or gases. Suitable for high pressure as well as extreme process temperature applications from -70 up to +400°C (-94 to 750°F). Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. Designed according to IEC 61508 for use in SIL2/3 safety applications.

Benefits

  • Large variety of different process connections and membrane materials

  • New TempC Membrane minimizes influences of ambient and process temperature fluctuations

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

  • Highest safety due to gastight feedthrough with capabilities up to SIL2/3, certified to IEC 61508

  • Cost savings with modular concept for easy replacement of sensor, display or electronics

  • Overload-resistant and function-monitored from the measuring cell to the electronics

Field of application

Two chamber aluminum or stainless steel (316L) housing.

  • Process connections: Threads, flanges or hygienic connections

  • Process temperature: -70 to +400°C (-94 to +752°F)

  • Pressure: -1/0 up to 400bar (-15/0 up to +6,000psi)

  • Accuracy: ±0.075%

  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals

Features and specifications

Continus Liquids  
Measuring Principle Hydrostatic
Characteristic / Application Digital transmitter with piezoresistive sensor and diaphragm seal
Modular transmitter
Long term stability
Minimum oil volume
Enhanced safety via self diagnostic functions
Secondary process barrier
Supply / Communication 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Accuracy 0,075% + influence of diaphragm seal
Long term stability 0,05% of URL/year
Ambient temperature -40°C...85°C
(-40°F...185°F)
Process temperature -70°C...400°C
(-94°F...752°F)
Process pressure absolute / max. overpressure limit 1050bar (15,200psi)
Pressure measuring range 100mbar...400bar
(1.5psi...5800psi)
Main wetted parts Alloy C276
316L
Monel
Tantalum
PTFE-Foil
Process connection Threads
Flanges (DIN, ASME, JIS) with flush membrane
Tri-Clamp ISO02852
Hygienic connections
Max. measurement distance 7000m (22.966ft) H2O
Output 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
SIL
WHG/ Overfill prevention
EN10204-3.1
NACE
Marine
Options HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing

Specialities Diagnostic functionalities
Different languages in software
Application limits Measuring cell: Metal welded
If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure
Pressure  
Measuring Principle Hydrostatic
Characteristic Digital transmitter with piezoresistive sensor and diaphragm seal
Modular transmitter
Long term stability
Minimum oil volume process connection
Enhanced safety via self diagnostic functions
Secondary process barrier
Supply voltage 4...20mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)

Reference Accuracy 0,075% + influence of diaphragm seal
Long term stability 0,05% of URL/year
Process temperature -70°C...400°C
(-94°F...752°F)
Ambient temperature -40°C...85°C
(-40°F...185°F)
Measuring cell 100mbar...700bar
(1.5psi...10.150psi)
relative/ absolute
Smallest calibratable span 5 mbar (0.075 psi)
Vacuum resistance 10 mbar (1.45 psi)
Max. Turn down 100:1
Max. overpressure limit 1050bar (15.750psi)
Process connection Thread:
G1/2...G2, R1/2, MNPT1/2...MNPT2, NPT1/2...NPT1
Flange:
DN25...DN100,
ASME 1"...4",
JIS 10K
Diaphragm seal
Hygienic Tri-Clamp
DIN11851
NEUMO
Varivent
SMS
DRD
Universal adapter
Material process membrane 316L, AlloyC,
Tantal
Rhodium> Gold
PTFE
Material gasket None, diaphragm welded
Fill fluid Silicone oil,
Inert oil,
Vegetable oil,
High temperature oil,
Low temperature oil,

Material housing Die-cast aluminum,
AISI 316L
Output 4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
Overfill prevention WHG
SIL
EN10204-3.1
NACE
3A, EHEDG
GL/ ABS Marine
Options HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing

Specialities Diagnostic functions
TempC Membrane