Field of application
Memosens CPS16E is suitable for simultaneous pH and ORP measurement in applications with long-term stable conditions. Thanks to its pH and ORP elements, the sensor offers a better process overview and enables tighter process control. Memosens CPS16E features Memosens 2.0 digital technology, offering extended data storage for predictive maintenance. The pH/ORP sensor resists moisture and enables lab calibration which makes the operator's daily tasks easier and maximizes process integrity.
-
Long-term monitoring or limit control in processes with stable process conditions:
- Chemical processes
- Pulp and paper industry
- Power stations (e.g. flue gas cleaning)
- Incinerator plants
- Mining
- Wastewater
-
Water treatment:
- Drinking water
- Cooling water
- Well water
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
|
Benefits
-
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
-
The additional platinum electrode enables constant monitoring of reference impedance and is a reliable indicator of the sensor quality.
-
Simultaneous measurement of pH, ORP and rH values (in rH mode) offers a better process overview and allows for a tighter process control.
-
Robust: Large PTFE ring junction and reference with ion trap prevent poisoning of the sensor.
-
Suitable for harsh applications: Process glass for highly alkaline media and pressure-stable up to 17 bar (246 psi).
-
Reduced operating costs: Lab calibration and fast sensor exchange on site minimize process downtime. Sensor regeneration in the laboratory extends the sensor lifetime.
-
Non-contact, digital signal transmission ensures reliable measurements resulting in maximum process safety.
|
-
-
Application
Long-term monitoring and limit control in processes with stable process conditions
• Chemical processes
• Pulp and paper industry
• Waste incinerators and gas scrubbers
• Mining
• Wastewater
-
Characteristic
Combination of pH and ORP electrode for standard applications in process technology and environmental engineering
Poison-resistant reference with ion trap
-
Measurement range
ORP: –1 500 to 1 500 mV
Application A
• pH: 1 to 12
Application B
• pH: 0 to 14
-
Measuring principle
Gel compact electrode with PTFE ring-junction and with ion trap
Pt-disc as additional ORP element
rH measurement and control of the reference impedance
-
Design
All shaft lengths with temperature sensor
Advanced gel technology
-
Material
Sensor shaft: Glass to suit process
pH membrane glass: Type A, B
Metal lead: Ag/AgCl
Open aperture: PFTE junction, sterilizable
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide
-
Dimension
Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225 and 360 mm
(4.72, 8.86, 14.17 and 16.73 inch)
-
Process temperature
Application A: –15 to 80 °C (5 to 176 °F)
Application B: 0 to 135 °C (32 to 275 °F)
-
Process pressure
0.8 to 17 bar (11.6 to 246,5 psi) absolute
-
-
Ex certification
With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2
-
Connection
Inductive, digital connection head with Memosens 2.0 technology
-
|
CPS16D-7BT21 is replaced by CPS16E-AA7BTA2
|
Basic model
|
|
Memosens CPS16D
|
|
|
|
Version:
|
7
|
Basic version
|
|
|
|
Application Range:
|
BT
|
0-14pH; 0-135oC; ORP -1500-1500 mV; rH value; 16 bar; with Ion trap
|
|
|
|
Shaft Length:
|
2
|
120 mm
|
|
|
|
Approval:
|
1
|
Non-hazardous area
|
|
|
|
CPS16E-AA7BTA2
-
Approval
AA
Non-hazardous area
-
Electrode Type
7
Basic version, zero point pH 7,0,ORP,rH value, temperature sensor NTC 30k
-
Application Range
B
0-14 pH, 0...135oC, 0,8...17 bar (abs)ORP Platinum, -1500...1500 mV
-
Reference System
TA
PTFE ring junction, ion trap,3 M KCl, Ag/AgCl
-
|
CPS16D-7AT21 is replaced by CPS16E-AA7ATA2
|
Basic model
|
|
Memosens CPS16D
|
|
|
|
Version:
|
7
|
Basic version
|
|
|
|
Application Range:
|
AT
|
1-12pH; -15-80oC; ORP -1500-1500mV; rH value; 6 bar; with Ion trap
|
|
|
|
Shaft Length:
|
2
|
120 mm
|
|
|
|
Approval:
|
1
|
Non-hazardous area
|
|
|
|
CPS16E-AA7ATA2
-
Approval
AA
Non-hazardous area
-
Electrode Type
7
Basic version, zero point pH 7,0,ORP,rH value, temperature sensor NTC 30k
-
Application Range
A
1-12 pH, -15...80oC, 0,8...17 bar (abs)ORP Platinum, -1500...1500 mV
-
Reference System
TA
PTFE ring junction, ion trap,3 M KCl, Ag/AgCl
-
|
|
|