Allen Bradley 1756-EN2T CLX ENet/IP 100M

  • Product Item : 1756-EN2T
  • Category: Allen-Bradley
  • Supporting protocol for EtherNet/IP:Yes
  • Power dissipation:5.1 W
  • Thermal dissipation:17.4 BTU/h
  • Communication rate:10/100 Mbps
  • INQUIRY   EMAIL
Catalog #: 1756-EN2T

CLX ENet/IP 100M


Technical Specifications

Electrical

With optical interface No
Supporting protocol for TCP/IP Yes
Supporting protocol for DeviceNet No
Supporting protocol for other bus systems No
Redundancy No
IO link master No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP Yes
Power dissipation 5.1 W
Thermal dissipation 17.4 BTU/h
Enclosure type rating None (open-style)
Ethernet ports 1 Ethernet RJ45 Category 5
CIP unconnected messages 128 + 128 (backplane + Ethernet)
Current draw 1 A @ 5.1V DC, 3 mA @ 24V DC
Ethernet cable 802.3 compliant shielded or unshielded twisted pair
Wiring category 2 - on Ethernet ports, 3 - on USB ports
Communication rate 10/100 Mbps
Connections supported, max TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for example, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.)
Isolation voltage 30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet(Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC for 60 s
Supporting protocol for LON No
Supporting protocol for ASI No
Supporting protocol for PROFIBUS No
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for KNX No
Supporting protocol for Modbus No
Supporting protocol for Data-Highway No
Supporting protocol for SUCONET No
With potential separation No
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
Radio standard Bluetooth No
Radio standard Wi-Fi 802.11 No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Radio standard GPRS No
Radio standard GSM No
Radio standard UMTS No
Slot width 1
ATEX temp code T4

Environmental

Surrounding air temperature, max 60 °C
Storage temperature -40 °C
Emissions CISPR 11: Class A
Vibration 2 G @ 10...500 Hz
ESD immunity 6 kV contact discharges, 8 kV air discharges
EFT/B immunity ±3 kV at 5 kHz on Ethernet ports
Relative humidity 5...95% noncondensing
Shock Operating: 30 G, Nonoperating: 30 G
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity ±2 kV line-earth (CM) on Ethernet ports
Operating temperature 0 °C
Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3V/m with 1 kHz sine-wave 80% AM from 2000...6000 MHz

Certification

North American temperature code T4A
IECEx temperature code T4

Mechanical

Module location Chassis based, any slot

Documentation

RESOURCE PUBLICATION NUMBER
Installation Instructions 1756-IN603

Certifications

China CCC ATEX
  • China CCC
  • Safety
  • American Bureau of Shippin
  • ATEX
  • CE