Home      Products     Endress+Hauser     Level       FTC260 Capacitance Point level detection
  • FTC260 Capacitance Point level detection

FTC260 Capacitance Point level detection

  • Product Item : FTC260-AA4D1
  • Category: Level
  • Measuring Principle:Capacitive Solid
  • Characteristic / Application:compact rod probe with build up compensation easy start up
  • Process connection:R1" NPT1"
  • Sensor length:140 mm (5.51")
  • INQUIRY   EMAIL

Capacitance Point level detection Minicap FTC260

Designed for light bulk solids


Minicap FTC260 is a simple and cost-effective rod probe for point level detection in bulk solids, particularly suited to applications involving aggressive media and heavy build-up. It is designed for point level detection of light bulk solids, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

Benefits

  • Simple mounting and commissioning without calibration

  • Mechanical safety, cost-efficiency and long operating life due to no wearing parts

  • High operational safety and reliability due to active build-up compensation

Field of application

For point level detection of light bulk solids, with a grain size up to max. 30mm and a dielectric constant εr ≥ 1.6.
Typical applications: Grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

  • Process connection: Threads

  • Temperature: -40 to +80°C (-40 to +176°F)

  • Pressure: -1 to +25bar (-14.5 to +360psi)

  • Sensor length: 140mm (5.51")

  • International explosion protection certificates, overfill prevention WHG

Features and specifications

Point Level / Solids  
Measuring Principle Capacitive Solid
Characteristic / Application compact rod probe with build up compensation
easy start up
Supply / Communication 10,8 ... 45V DC, DC-PNP 3-wire
20 ... 253V AC, or
20 ... 55V DC, Relay output

Ambient temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process temperature -40 °C ... 130°C
(-40 °F ... 266 °F)
Process pressure absolute / max. overpressure limit -1 ... 25 bar
(-14.5 ... 360 psi)
Main wetted parts PPS = Polyphenylene sulphide
(glass fibre content approx. 40%)
Process connection R1"
NPT1"
Sensor length 140 mm (5.51")
Communication PNP transistor output
Relay output (potential-free
change-over contact / SPDT)
Certificates / Approvals ATEX , FM, CSA, NEPSI
WHG