Home      Products     Endress+Hauser     Level       FMP50 Guided radar measurement
  • FMP50 Guided radar measurement

FMP50 Guided radar measurement

  • Product Item : FMP50-BAACCDLAA1GDJ
  • Category: Level
  • Measuring Principle:Guided radar
  • Characteristic / Application:Basic device  Rod probe, Rope probe  Integrated data memory, Factory precalibrated, Reliable measuring for changing medias. 
  • Supply / Communication:2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART) 
  • Process connection:Thread: G 3/4, MNPT 3/4 Flange: UNI Flange
  • INQUIRY   EMAIL

Guided radar measurement Time-of-Flight Levelflex FMP50

For all basic level applications in liquids


Levelflex FMP50 is the instrument for basic applications in liquids which do not place high demands on temperature and pressure ranges or chemical resistance. Particularly in basic supply or storage applications as well as utility processes FMP50is the best choice. Levelflex FMP50 guided radar is used for continuous level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Benefits

  • Reliable measurement even for changing product and process conditions

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Highest reliability due to new Multi-Echo Tracking evaluation

  • Hardware and software developed according to IEC 61508 up to SIL3

  • Seamless integration into control or asset management systems

  • Intuitive, menu-guided operation concept (on-site or via the control system) in national languages reduces costs for training, maintenance and operation

  • World's easiest proof test for SIL and WHG saves time and costs

Field of application

Version with rod or rope probe.

  • Process connections: Thread or adapter flange

  • Temperature: -20 to +80°C (-4 to +176°F)

  • Pressure: -1 to +6bar (-14.5 to +87psi)

  • Maximum measuring range: Rod 4m (13ft), rope 12m (39ft)

  • Accuracy: ±2mm (0.08")

  • International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol

Features and specifications

Measuring Principle Guided radar
Characteristic / Application Basic device
Rod probe, Rope probe
Integrated data memory, Factory precalibrated, Reliable measuring for changing medias.
Supply / Communication 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Accuracy Rod probe: +/- 2 mm (0.08 in)
Rope probe: +/- 2 mm (0.08 in)
Ambient temperature -40...+80 °C
(-40...+176 °F)
Process temperature -20...+80 °C
(-4...+176 °F)
Process pressure absolute / max. overpressure limit Vacuum...6 bar,
(Vacuum...87 psi)
Main wetted parts Rod probe: 316L, PPS, Viton
Rope probe: 316, PPS, Viton
Process connection Thread:
G 3/4, MNPT 3/4
Flange:
UNI Flange
Sensor length Rod probe: 4 m (13 ft)
Rope probe: 12 m (40 ft)
Max. measurement distance Rod: 4 m (13 ft) Min DK>1.6
Rope: 12 m (40 ft) Min DK>1.6
Output 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus

Certificates / Approvals ATEX, FM, CSA, CSA C/US, IECEx, NEPSI, KC, INMETRO
Overfill prevention WHG
SIL
EN10204-3.1
Options Sensor remote with 3 m/9 ft cable
Application limits Horizontal storage tank cyl.:
use coax probe
Corrosive liquids:
FMP52
High pressure/ temperatures >80°C/176°F; 6bar/87psi:
FMP51, FMP54
Interface measurement
FMP51, FMP55