Home      Products     Endress+Hauser     Pressure       FMD71 Electronic differential pressure
  • FMD71 Electronic differential pressure
  • FMD71 Electronic differential pressure
FMD71 Electronic differential pressureFMD71 Electronic differential pressure

FMD71 Electronic differential pressure

  • Product Item : FMD71-AA24AAC1H1HGDBCCCTIJ
  • Category: Pressure
  • Measuring Principle:Differential pressure
  • Characteristic / Application:Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids.
  • Supply / Communication:4...20 mA HART: 12...45V DC Exia: 12...30V DC
  • Communication:4...20 mA HART
  • INQUIRY   EMAIL

Electronic differential pressure Deltabar FMD71

Electronic differential pressure system utilizing two ceramic sensor modules and one transmitter


The electronic dp Deltabar FMD71 is a differential pressure system, used to measure the pressure or level, volume or mass of liquids in pressurized tanks or distillation columns/evaporators. The high pressure sensor (HP) measures the hydrostatic pressure. The low pressure sensor (LP) measures the head pressure. The level is calculated in the transmitter using these two digital values. The electronic dp system eliminates issues of traditional differential pressure measurements.

Benefits

  • Eliminates traditional mechanical issues resulting in greater process availability and reliability

  • Overload-resistant high purity ceramic sensor (99.9% Al2O3)

  • Safety risks are minimized with the new electronic differential pressure system architecture and design

  • Lowest total cost of ownership due to reduced installation time, maintenance, downtime and spare requirements

  • Multivariable level measurement: HART-based differential pressure, head pressure and sensor temperatures from one system

  • Continuous health indication of the entire system via HART-based diagnostic

  • High reproducibility and long-term stability

Field of application

For differential pressure, level, volume or mass measurement of liquids in pressurized tanks and distillation columns/evaporators.

  • Process connections: Threads, flanges and hygienic connections

  • Process temperature: -40 up to +150°C (-40 to +302°F)

  • Measuring range: 100mbar to +40bar (6 to 600psi)

  • Accuracy: Single sensor up to ±0.05%, system up to ±0.07%

  • International explosion protection certificates, hygienic approvals

Features and specifications

Continuous / Liquids  
Measuring Principle Differential pressure
Characteristic / Application Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids.
Supply / Communication 4...20 mA HART:
12...45V DC
Exia: 12...30V DC

Accuracy 0.075% of individual sensor,
"PLATINUM" 0.05% of individual sensor
Long term stability 0.05% of URL/year of individual sensor
Ambient temperature –40...+80°C
(–40...+176°F)
Process temperature –25...+150°C
(–13...+302°F)
Process pressure absolute / max. overpressure limit 60 bar (900 psi)
Pressure measuring range 100mbar...40bar
(1.5psi...600psi)
Process connection Threads
Flanges (DIN, ASME, JIS)
Process connection hygienic DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent
Communication 4...20 mA HART

Certificates / Approvals ATEX, FM, CSA, IECEx
NACE,
EN10204-3.1,
EHEDG,
3A
Pressure  
Measuring Principle Differential pressure
Characteristic Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids.
Supply voltage 4...20 mA HART:
12...45V DC (Non Ex)
Ex ia: 12...30V DC

Reference Accuracy 0.075% of individual sensor,
"PLATINUM" 0.05% of individual sensor
Long term stability 0.05% of URL/year of individual sensor
Process temperature –25...+150°C
(–13...+302°F)
Ambient temperature –40...+80°C
(–40...+176°F)
Measuring cell 100 mbar...40 bar
(1.5 psi...600 psi)
Vacuum resistance 0 mbar abs.
Max. Turn down 100 : 1
Max. overpressure limit 60 bar (900 psi)
Process connection Threads
Flansch (DIN, ASME, JIS)
Hygienic DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent
Material process membrane Ceramic
316L, AlloyC
Material gasket Viton, Kalrez, EPDM, NBR, Silicone
Fill fluid Silicone Oil
Material housing Die-cast aluminum
Stainless steel
Communication 4...20 mA HART

Certificates / Approvals ATEX, FM, CSA, IECEx

Design approvals NACE MR0175,
EN10204-3.1,

Hygienic approvals EHEDG,
3A