  • Product Item : FMB52-DTQ5/0
  • Category: Level
  • Measuring Principle:Hydrostatic
  • Accuracy:Standard 0,2%  Optional 0,1%
  • Pressure measuring range:100mbar...10bar  (1.5psi...150psi) 
  • Communication:4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus 
  • INQUIRY   EMAIL

Hydrostatic Level measurement Deltapilot FMB52

Pressure sensor with Contite measuring cell for hydrostatic level measurement


The Deltapilot FMB52 is a cable version including a fixed process connection. This device with the Contite measuring cell is typically used in the process and environmental industries. It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation. For use in SIL2 safety systems.

Benefits

  • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects

  • Modular concept for easy replacement of display or electronics

  • Seamless and independent system integration (HART/PA/FF)

  • Easy and safe menu-guided operation: On-site via display module, via 4 to 20mA with HART, via PROFIBUS PA, via FOUNDATION Fieldbus

  • International usage thanks to a wide range of approvals

Field of application

For level measurement.

  • Process connections: Threads and flanges

  • Temperature: With PE cable: -10 to +70°C (+14 to +158°F),

    with FEP cable: -10 to +80°C (14 to 176°F)

  • Measuring range: 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O)

  • Accuracy: ±0.2%, ±0.1% (option)

  • International explosion protection certificates, overfill prevention WHG, SIL, drinking water approval

Features and specifications

Continuous / Liquids level
Measuring Principle Hydrostatic
Characteristic / Application Pressure transmitter for Pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
- hermetically welded
- absolute condensation tight
- climate-resitant
- long-term stable
- Lowest temperature influences

Cable version
Supply / Communication 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC (Non Ex)
Accuracy Standard 0,2%
Optional 0,1%
Long term stability 0,05% of URL/year
Ambient temperature -40°C...85°C
(-40°F...185°F)
Process temperature PE cable: -10°C…70°C / 14°F…158°F
FEP cable: -10°C…80°C / 14°F…176°F
Process pressure absolute / max. overpressure limit 40 bar (600 psi)
Pressure measuring range 100mbar...10bar
(1.5psi...150psi)
Main wetted parts Alloy C
316L
Cable (PE/FEP)
optional coating AuPt
optional coating AuRh
Process connection Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 2"...4",
JIS 10K
Max. measurement distance 100m (328ft) H2O
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

Safety approvals Overfill prevention WHG
SIL

Design approvals EN10204-3.1
NACE MRO175

Marine approval GL/ ABS/ LR/ BV/ DNV

Drinking water approvals KTW/ NSF/ ACS

Pressure measurement
Measuring Principle Hydrostatic
Characteristic Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
- hermetically welded
- absolute condensation tight
- climate-resitant
- long-term stable
- Lowest temperature influences

Cable version
Supply voltage 4...20mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)

Reference Accuracy Standard 0,2%
Optional 0,1%
Long term stability 0,05% of URL/year
Process temperature PE cable: -10°C…70°C / 14°F…158°F
FEP cable: -10°C…80°C / 14°F…176°F
Ambient temperature -40°C...85°C
(-40°F...185°F)
Measuring cell 100mbar...10bar
(1.5psi...150psi)
Smallest calibratable span 10 mbar (1.45 psi)
Vacuum resistance 0 mbar abs.
Max. Turn down 100:1
Max. overpressure limit 40 bar (600 psi)
Process connection Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 2"...4",
JIS 10K
Material process membrane 316L, AlloyC,
Gold-Rhodium
PE, FEP
Material gasket Viton, EPDM, Kalrez, none
Fill fluid Inert oil,
Synthetic oil
Material housing 316L, Die-cast aluminum
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

Safety approvals Overfill prevention WHG
SIL

Design approvals EN10204-3.1
NACE MR0175

Marine approvals GL/ ABS/ LR/ BV/ DNV

Drinking water approvals KTW/ NSF/ ACS

Specialities Modularity to differential pressure and process pressure devices (replacable display, universal electronics)

Diagnostic functions

Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)