Home      Products     Endress+Hauser     Flowmeter       10L Electromagnetic flowmeter
  • 10L Electromagnetic flowmeter

10L Electromagnetic flowmeter

  • Product Item : 10L2H-QC0A1AA0A5AA
  • Category: Flowmeter
  • Measuring Principle:Electromagnetic
  • Measuring Principle:Electromagnetic Product headline The flowmeter with a weight‐optimized sensor and highly cost‐effectiveness. Fully suitable for standard applications in the water and wastewater
  • Wetted materials:Liner: PTFE; Polyurethane; Hard rubber  Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
  • Outputs:4‐20 mA HART (active) Pulse/switch output (passive)
  • Attachment INQUIRY   EMAIL

Proline Promag 10L Electromagnetic flowmeter

The flowmeter with a weight-optimized sensor and highly cost-effectiveness


Promag L is the versatile standard sensor for the water and wastewater industry with a lap-joint flange concept for flexible installation independent of the orientation of the pipe flange pitch diameter. Combined with the Promag 10 transmitter for basic applications and direct integration, Promag 10L offers accurate measurement of liquids for a wide range of applications. It will be the preferred solution for customers aiming for minimized cost of ownership.

 

Benefits

  • Reduced installation costs – flexible mounting by one-of-a-kind lap-joint flange concept (DN < 350/14")

  • Energy-saving flow measurement – no pressure loss due to cross-section constriction

  • Cost-effective – designed for easy applications and direct integration

  • Safe operation – display provides easy readable process information

  • Fully industry compliant – IEC/EN/NAMUR

  • Maintenance-free – no moving parts

Field of application

  • The measuring principle is virtually independent of pressure, density, temperature and viscosity

  • Fully suitable for standard applications in the water and wastewater industry.

Device properties

  • Up to 30 % less sensor weight

  • Nominal diameter: DN 25 to 2400 (1 to 90")

  • Maximum reduced installation length to DVGW/ISO

  • 2-line display with push buttons

  • Device in compact or remote version

  • HART

Features and specifications

Liquids
Measuring Principle Electromagnetic
Product headline The flowmeter with a weight‐optimized sensor and highly cost‐effectiveness. Fully suitable for standard applications in the water and wastewater industry.
Sensor features Reduced installation costs – flexible mounting by one‐of‐a‐kind lap‐joint flange concept (DN <350/14"). Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Up to 30 % less sensor weight. Nominal diameter: DN 25 to 2400 (1 to 90").
Transmitter features Cost‐effective – designed for easy applications and direct integration. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line display with push buttons. Device in compact or remote version.
Nominal diameter range Lap joint flange; lap joint flange, stamped plate: DN 25 to 300 (1 to 12")
Fixed flange: DN 350 to 2400 (14 to 90")
Wetted materials Liner: PTFE; Polyurethane; Hard rubber
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables Volume flow
Max. measured error Volume flow: ±0.5 % o.r. ± 2 mm/s (±0.5 % o.r. ± 0.08 in/s)
Measuring range 9 dm³/min to 162 000 m³/h (2.5 gal/min to 1030 Mgal/d)
Max. process pressure PN 16, Class 150
Medium temperature range Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Ambient temperature range Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
Sensor housing material DN 25 to 300 (1 to 12"): AlSi10Mg, coated
DN 350 to 2400 (14 to 90"): Carbon steel with protective varnish
Sensor connection housing: AlSi10Mg, coated
Transmitter housing material Powder‐coated die‐cast aluminum
Degree of protection Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure
Transmitter remote version: IP67, type 4X enclosure
Display/Operation 2-line display with push buttons
Configuration via local display and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/switch output (passive)
Inputs None
Digital communication HART
Power supply DC 11 to 40 V
AC 85 to 250 V (45 to 65 Hz)
AC 20 to 28 V (45 to 65 Hz)

Hazardous area approvals cCSAus
Other approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Drinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920