  • Product Item : CLS15E-AAHC10A
  • Category: Analysis
  • Measuring principle:Conductive
  • Characteristic Digital 2-electrode conductivity sensor
  • Material Electrode: stainless steel 1.4435 Electrode shaft: PES
  • INQUIRY   EMAIL

Digital conductivity sensor
Memosens CLS15E replace CLS15D

Memosens 2.0 contacting conductivity sensor for standard applications in pure and ultrapure water


Field of application

Memosens CLS15E is perfectly suited for conductivity measurement in applications with low measuring ranges such as boiler feedwater and chip cleaning. The contacting conductivity sensor performs reliably and accurately even in hazardous areas. CLS15E features Memosens 2.0 digital technology, offering extended storage of calibration, adjustment and process data. It facilitates predictive maintenance and provides the perfect basis for IIoT services.

Memosens CLS15E measures conductivity in pure and ultrapure water applications for the monitoring and control of:

  • Boiler feedwater

  • Ion exchangers

  • Reverse osmosis

  • Cooling water

  • Distillation

  • Chip cleaning

The digital sensor can be used in power plants for:

  • Degassed conductivity

  • pH measurement with differential conductivity

With its international explosion protection approvals, such as ATEX and FM, the sensor is suitable for hazardous area use.


Benefits

  • Designed for low maintenance and a long operating life, the sensor offers best value for money.

  • The sensor is sterilizable and autoclavable, allowing for installation in sterile plants.

  • Thanks to its electrode geometry, Memosens CLS15E provides reliable and accurate measured values at low conductivities.

  • A quality certificate stating the individual cell constant enables perfect adjustment of the measuring point.

  • IIoT ready: Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.

  • Non-contact inductive signal transmission ensures maximum process safety.


  • Measuring principle

    Conductive

  • Application

    Measurement in pure and ultrapure water range
    Monitoring of ion exchangers
    Reverse osmosis
    Distillation and chip cleaning

  • Characteristic

    Digital 2-electrode conductivity sensor

  • Measurement range

    k=0,01: 0.04 to 20 µS/cm
    k=0,1: 0.10 to 200 µS/cm

  • Measuring principle

    Conductive conductivity cell with electropolished stainless steel electrodes

  • Design

    2-electrode conductivity cell with coaxially arranged electrodes, electropolished

  • Material

    Electrode: stainless steel 1.4435
    Electrode shaft: PES

  • Dimension

    Electrode diameter: 16 mm (0.63 inch)
    Electrode length: appr. 55 mm (2.17 inch)

  • Process temperature

    Threaded with fixed cable:
    -20 to 100 °C (-4 to 212 °F)
    Threaded with plug-in head:
    -20 to 120 °C (-4 to 248 °F)
    Sterilization: max. 140 °C (284 °F) for 30 minutes

  • Process pressure

    13 bar at 20 °C (188 psi at 68 °F) absolute
    1 bar at 120 °C (14 psi at 248 °F) absolute

  • Temperature sensor

    Pt1000

  • Ex certification

    ATEX, NEPSI, CSA, IECEx, INMETRO, EAC Ex

  • Connection

    Process: 1/2" and 3/4" NPT, Clamp 1 1/2"
    Sensor connection: Inductive, digital connection head with Memosens 2.0 technology

  • Ingress protection

    IP68

  • Additional certifications

    Calibration certification of the cell constante and temperature, material certification 3.1


CLS15E-AAHC10A


  • Approval
    AA
    Non-hazardous area
  • Process Connection
    HC
    Thread NPT1/2
  • Material
    10
    Sensor PES, electrodes 1.4435
  • Cell Constant
    A
    K=0.01


CLS15D-A1A1 replaced by CLS15E-AAHC10A

Basic model
Condumax CLS15D
Measuring Range; Cell Constant:
A 0.04-20uS/cm; k=0.01
Process Connection:
1A thread NPT 1/2"; PES
Approval:
1 non hazardous area

CLS15E-AAHC10A

  • Approval
    AA
    Non-hazardous area
  • Process Connection
    HC
    Thread NPT1/2
  • Material
    10
    Sensor PES, electrodes 1.4435
  • Cell Constant
    A
    K=0.01