Proline Prosonic Flow 93T Ultrasonic flowmeter

The economical flowmeter for easy data transfer via USB stick without additional software


The portable ultrasonic flowmeter Prosonic Flow 93T is designed for temporary monitoring and test measurements with clamp on sensors. It is operated independently of the mains power using a battery. The Prosonic Flow 93T is ideal for conducting verification measurements at existing flow metering points.

 

Benefits

  • Automatic frequency scan for maximum measuring performance

  • Quick and secure installation – specially designed mounting kits

  • No additional leakage paths – external measurement from outside the pipe

  • Process transparency – diagnostic capability

  • Temporary monitoring of measuring points – portable flowmeter with rechargeable battery and current output

  • Verification of other flow devices – integrated data logger and current input

  • Automatic recovery of data

Field of application

The sensors are perfectly suited for the non-contact measurement of pure or slightly contaminated liquids, regardless of the pressure or electrical conductivity.

  • Ideal solution for temporary use everywhere precise measurement or verification is required

  • Can be used with all metal and plastic pipes lined or unlined and with composite pipes

  • Suitable for pipe diameters from DN 15 to 4000 (½ to 160")

  • Suitable for fluid temperatures ranging from –40 to +170 °C (–40 to +338 °F)

Features and specifications

Continuous / Liquids
Measuring Principle Ultrasonic
Characteristic / Application Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
Supply / Communication 4-wire (HART, Profibus DP)
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process pressure absolute / max. overpressure limit 0.7 bar ... 4 bar abs
(10 psi ... 58 psi)
Main wetted parts PVDF (fully welded IP68 / NEMA6P)
Process connection G / NPT 1"
Blocking distance 0.3 m (1 ft)
Max. measurement distance 10 m (33 ft)
Output Transmitter:
4 ... 20 mA HART
Profibus DP

Certificates / Approvals ATEX, FM, CSA, IEC Ex, TIIS, NEPSI

Options Second 4...20mA output
Application limits Foam / high turbulence possible:
FDU92
Flange-flush assembly:
FDU91F
For tank farms scanner:
FMU95

Components Transmitter:
FMU90, FMU95
Continuous / Solids
Measuring Principle Ultrasonic
Characteristic / Application Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
Supply / Communication 4-wire (HART , Profibus DP)
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process temperature -40 °C ... 80 °C
(-40 °F ... 176 °F)
Process pressure absolute / max. overpressure limit 0.7 bar ... 4 bar abs
(10 psi ... 58 psi)
Main wetted parts PVDF (fully welded IP68 / NEMA 6P)
Process connection G / NPT 1"
Blocking distance 0.3 m (1 ft)
Max. measurement distance 5 m (16ft)
Output Transmitter:
4 ... 20 mA HART
Profibus DP

Certificates / Approvals ATEX, FM, CSA, IEC Ex, TIIS, NEPSI

Options Second 4...20mA output
Components Transmitter:
FMU90
Liquids
Measuring Principle Ultrasonic
Product headline Version with separate transmitter in field housing or top hat rail housing
Cost effective solution for open channel flow measurement in water / wastewater plants
Max. measured error accuracy:
distance measurement: +/- 2mm + 0.17%
resolution:
distance measurement: 1mm

Measuring range max measuring distance up to 10m / 32ft
Max. process pressure atm.
Medium temperature range -40...80°C
(-40...176°F)
Degree of protection IP68
Display/Operation Transmitter
Outputs Transmitter:
4...20mA HART
Option: second 4...20mA output
Inputs Transmitter
Digital communication PROFIBUS DP
HART
Hazardous area approvals ATEX
IECEx
FM