Turbimax CUE21 / CUE22

Application

                    On-line continuous monitoring of clean water:  • Drinking water  • Treated process water

Your benefits

                    • Versions with white light source and infrared light source   available

                    • Fast and easy calibration  – Complete primary calibration in less than 5 minutes  – Verification in seconds

                    • Reduced calibration costs and quick response times thanks to   low volume sample chamber

                    • Automatic continuous ultrasonic cleaning (Autoclean)   increases cleaning intervals dramatically  • Simple modular design  • Easy to use and service

                    • Affordable thanks to modular microprocessor based   technology

                    • Digital high-speed connections through RS-485 with Modbus  Optional Features:

                    • Flow chamber for bubble suppression

                    • Reusable calibration ki


Function and system design
                Measuring principle


                    Turbidity measurement  For turbidity measurement a light beam is sent through the medium and is diverted from its original direction   by optically denser particels, e.g. solid matter particles.

                Measuring methods


                    90° WL scattered light method  The measurement uses the standardised 90° scattered light method acc. to U.S. EPA 180.1.  The turbidity of the medium is determined by the amount of scattered light. The transmitted white light beam   is scattered by the solid matter particles in the medium. The scattered beams are detected by scattered light   receivers which are arranged at an angle of 90° to the white light source.  90° NIR scattered light method  The measurement uses the standardized 90° scattered light method acc. to ISO 7027 / EN 27027.  The turbidity of the medium is determined by the amount of scattered light. The transmitted light beam with   a wavelength in the near-infrared range is scattered by the solid matter particles in the medium. The scattered   beams are detected by scattered light receivers which are arranged at an angle of 90° to the infrared light   source



                    Measuring system


The Turbimax CUE21 / CUE22 measuring system comprises:

                    • Turbimax turbidimeter with installed cuvette and desiccant pouch
                    • Connecting tubing with
                    – fittings for flow through assembly
                    – shutoff clamp
                    – backpressure valve
                    – drain vent screw (in pressurized systems)

                    • Sensor interconnect cable





Input

                    Measured variables
                    Turbidity
                    Measuring range
                    CUE21: 0 to 1000 NTU /FNU
                    CUE22: 0 to 100 NTU /FNU




Output

                    Output signal
                    4 to 20 mA, galvanically isolated
                    Signal on alarm
                    2 mA in case of an error
                    Load
                    max. 600 Ω
                    Communications port
                    Bi-directional RS-485, Modbus optional
                    Relays
                    Switching voltage: max. 240 VAC
                    Switching current: max. 2 A
                    Limit value and alarm
                    functions
                    Setpoint adjustment:
                    CUE21:
                    CUE22:
                    0 to 1000 NTU
                    0 to 100 NTU
                    Alarm delay: 0 to 30 s


                      




                    Power supply
                    Electrical connection
                    Power supply
                    100 to 240 VAC, 47 to 63 Hz, 80 VA switching power supply

                    Installation
                    Wall mounting
                    Turbimax CUE21 / CUE22 is recommended for indoor use.
                    When mounting the instrument note the following:
                    • Check that the temperature does not exceed the maximum permitted operating temperature range
                    (0 to 50 °C (32 to 122 °F)).
                    • Leave a free area of approx. 0.20 m (8.00") above the instrument. This will ensure enough room for
                    calibration and cuvette maintenance.
                    • Mount the instrument as close as possible to the sampling point to ensure a quick response time

                        (within 2 to 3 m (6 to 10 ft)).



                    Ordering information
                    Turbimax CUE21
                    compact device, infrared
                    Turbimax CUE22
                    compact device, white light