Home      Products     Endress+Hauser     Level       FMR53 Radar measurement Time-of-Flight
  • FMR53 Radar measurement Time-of-Flight

FMR53 Radar measurement Time-of-Flight

  • Product Item : FMR53-AAACAACARVF+AK
  • Category: Level
  • Measuring Principle :Level radar
  • Characteristic / Application:For basic level measurement in liquids, pastes and slurries; non affected by changing media, temperature changes, gas blankets or vapor; Encapsulated PVDF or PP clad horn
  • Supply / Communication :2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART)
  • Frequency :K-band (~26 GHz)
  • INQUIRY   EMAIL

Radar measurement Time-of-Flight Micropilot FMR53

For simple level measurement applications in liquids


Micropilot FMR53 for simple level measurement applications in liquids. With its slim rod antenna, FMR53 free space radar is particularly suited for small process connections. The PTFE coating of the rod antenna and flange plating guarantee resistance also in aggressive media. The Micropilot FMR53 is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Benefits

  • Reliable non-contact measurement even for changing product and process conditions

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation

  • Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)

  • Seamless integration into control or asset management systems

  • Intuitive, menu-guided operation concept (on-site or via the control system)

  • World's easiest proof test concept for SIL and WHG saves time and cost

Field of application

Especially suited for small process connections, PTFE sensors usable in chemically aggressive media.

  • Process connections: Thread or flange

  • Temperature: -40 to +150°C (–40 to +302°F)

  • Pressure range: -1 to +40bar (–14.5 to +580psi)

  • Maximum measuring range: 20m (66ft)

  • Accuracy: ±6mm

  • C-band: 6GHz

  • International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol

Features and specifications

Continuous / Liquids  
Measuring Principle Ultrasonic
Characteristic / Application Separated version with Field housing or top hat rail housing for control cabinet instrumentation, up to 6 relays for pump / rake / limit control, 1 or 2 channel version
Supply / Communication 90 ... 253 VAC
10.5 ... 32 VDC
up to 2x 4...20mA HART
Profibus DP

Accuracy +/- 2mm + 0.17% of measured distance

Ambient temperature -40 °C ... 60 °C
(-40 °F ... 140 °F)
Communication up to 2x 4 ... 20 mA HART
Profibus DP

Certificates / Approvals FMU allowed to operate FDU9x in Ex-Zone
CSA GP (tested according UL)
Components Sensors FDU9x
Continuous / Liquids  
Measuring Principle Level radar
Characteristic / Application For common non-contact continuous level measurement in liquids,
especially suited for small process connections and for chemically aggressive media;
Rod antenna with PTFE coating
Supply / Communication 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)

Frequency C-band (~6 GHz)
Accuracy +/- 6 mm (0.24 in)
Ambient temperature -40...+80 °C
(-40...+176 °F)
Process temperature -40...+150 °C
(-40...+302 °F)
Process pressure absolute / max. overpressure limit Vacuum...40 bar
(Vacuum...580 psi)
Main wetted parts PTFE, PVDF
Process connection Thread:
MNPT 1 1/2, R 1 1/2
Flange:
DN50...DN150,
ASME 2"...6",
JIS 10K
Max. measurement distance 20 m (65 ft)
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus

Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, INMETRO, KC
Overfill prevention WHG
SIL
EN 10204-3.1