Turbimax CUE21 / CUE22 | |
Application On-line continuous monitoring of clean water: • Drinking water • Treated process water |
|
Your benefits • Versions with white light source and infrared light source available • Fast and easy calibration – Complete primary calibration in less than 5 minutes – Verification in seconds • Reduced calibration costs and quick response times thanks to low volume sample chamber • Automatic continuous ultrasonic cleaning (Autoclean) increases cleaning intervals dramatically • Simple modular design • Easy to use and service • Affordable thanks to modular microprocessor based technology • Digital high-speed connections through RS-485 with Modbus Optional Features: • Flow chamber for bubble suppression • Reusable calibration ki |
|
Function and system design | |
Measuring principle |
Turbidity measurement For turbidity measurement a light beam is sent through the medium and is diverted from its original direction by optically denser particels, e.g. solid matter particles. |
Measuring methods |
90° WL scattered light method The measurement uses the standardised 90° scattered light method acc. to U.S. EPA 180.1. The turbidity of the medium is determined by the amount of scattered light. The transmitted white light beam is scattered by the solid matter particles in the medium. The scattered beams are detected by scattered light receivers which are arranged at an angle of 90° to the white light source. 90° NIR scattered light method The measurement uses the standardized 90° scattered light method acc. to ISO 7027 / EN 27027. The turbidity of the medium is determined by the amount of scattered light. The transmitted light beam with a wavelength in the near-infrared range is scattered by the solid matter particles in the medium. The scattered beams are detected by scattered light receivers which are arranged at an angle of 90° to the infrared light source
|
Measuring system
|
The Turbimax CUE21 / CUE22 measuring system comprises:
• Turbimax turbidimeter with installed cuvette and desiccant pouch
• Connecting tubing with
– fittings for flow through assembly
– shutoff clamp
– backpressure valve
– drain vent screw (in pressurized systems)
• Sensor interconnect cable
|
Input |
|
Measured variables
|
Turbidity
|
Measuring range
|
CUE21: 0 to 1000 NTU /FNU
CUE22: 0 to 100 NTU /FNU
|
Output |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Output signal
|
4 to 20 mA, galvanically isolated
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Signal on alarm
|
2 mA in case of an error
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Load
|
max. 600 Ω
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Communications port
|
Bi-directional RS-485, Modbus optional
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Relays
|
Switching voltage: max. 240 VAC
Switching current: max. 2 A
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Limit value and alarm
functions
|
Setpoint adjustment:
CUE21:
CUE22:
0 to 1000 NTU
0 to 100 NTU
Alarm delay: 0 to 30 s
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Turbimax CUE21-A1A, compact infrared
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power supply
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electrical connection
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power supply
|
100 to 240 VAC, 47 to 63 Hz, 80 VA switching power supply
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Installation
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Wall mounting
|
Turbimax CUE21 / CUE22 is recommended for indoor use.
When mounting the instrument note the following:
• Check that the temperature does not exceed the maximum permitted operating temperature range
(0 to 50 °C (32 to 122 °F)).
• Leave a free area of approx. 0.20 m (8.00") above the instrument. This will ensure enough room for
calibration and cuvette maintenance.
• Mount the instrument as close as possible to the sampling point to ensure a quick response time
(within 2 to 3 m (6 to 10 ft)).
|
Ordering information
|
|
Turbimax CUE21
compact device, infrared
|
|
Turbimax CUE22
compact device, white light
|